JASH F.R.P.
WEIR GATES
|
|
| Specifications |
 |
| These gates are made as per JASH
design. |
| Application |
These gates are downward opening type gates and can
be used either for
- Decanting of a reservoir or a tank, or
- For maintaining precise level control in a reservoir or a tank, or
- To control the flow into or from a conduit as a sluice gate in
locations where clearance between the opening and the gate operating floor is inadequate
to allow raising of gate to fully open.
|
| Salient
Features |
- Flat back frame design for direct mounting on face of wall.
- Designed for channel application, breast wall not required.
- Suitable for seating head application.
- Rising spindle Self Contained gate with lift mechanism mounted
directly on gate frame.
- Complete continuous sealing on sides and bottom of gate aperture
at any position of shutter opening.
- Plastic to rubber sealing arrangement on three sides.
- Corrosion resistant material
- Light weight hence easy to install.
- Manual lift mechanism to enable a single person to operate gate
with effort < 20Kgs.
|
| Materials of
Construction |
| Depending upon application and requirement, the
client should select and specify the Materials of
Construction for various components from offered alternatives. |
| Shop Testing
Parameters |
- Seat clearance check for checking clearance between mating sealing
faces.
- Movement test for checking interference free movement of complete
assembly.
- Leakage test at atmospheric pressure if weir gate provided with
sealing on all four sides for application (iii) above.
|
| Optional Features |
- Electrically or Pneumatically operated lift mechanism with manual
overide facility.
- Gate opening indicating arrangement.
- Additional sealing on top side for flow control into or from a
conduit for application (iii).
- Lift mechanism mounted on platform away from gate frame.
|