JASH CAST IRON WEIR GATES
SPECIFICATION : These gates are made as per Jash design.
APPLICATION : These gates are downward opening type gates and
can be used either for
(i) Decanting of a reservoir or a tank, or
(ii) For maintaining precise level control in a reservoir or a tank.
SALIENT FEATURES OF CAST IRON WEIR GATE
| • |
Cast Iron Weir Gate is designed for decanting application and hence breast wall not
required. |
| • |
CI weir gates is perfect for seating / unseating head application. |
| • |
Flange / flat back frame designed for mounting on face of wall
using anchor bolts in Cast Iron Weir Gates
. |
| • |
Complete continuous water sealing on sides and bottom of CI weir gate
aperture at any position of shutter opening ensured by providing
non-corroding nonferrous sealing face on entire face of shutter.
This ensures long lasting sealing of weir gate. Where economy is a
consideration, the entire face of shutter may be provided just
finish machined only without nonferrous sealing face in ci weir
gate . |
| • |
Metal to metal sealing arrangement on three sides of Cast Iron
Weir Gates. |
| • |
Non ferrous metal facings on full face of shutter for effecting
long lasting water sealing in Cast Iron Weir Gates. |
| • |
Cast Iron Weir Gates has pin and knuckle type stem connecting arrangement
to connect the shutter with the spindle. |
| • |
Single piece rising spindle to connect the shutter to the
weir gate operating arrangement. |
| • |
Manual lift mechanism to enable a single person to operate gate
with effort < 20Kgs. |
| • |
Offered with painting as required by the client or as stated on
page no. . |
MATERIALS OF CONSTRUCTION :
Depending on application and requirement, the client may select and
specify the material of construction for various components from the
alternatives provided herein.

SHOP TEST PARAMETERS :
• Seat clearance check for checking clearance between mating sealing
faces.
• Movement test for checking interference free movement of complete
gate assembly.
OPTIONAL FEATURES :
• Metal to rubber sealing arrangement.
• Mechanical or chemical anchor fasteners.
• Wall thimble mounting.
• Self Contained gate with lift mechanism mounted directly on gate
frame.
• Stem cover either made of galvanized steel or transparent tube.
• Gate opening indicating arrangement.
• Non rising spindle.
• Electrically operated lift mechanism with manual override
facility.
• Pneumatically operated lift mechanism with manual override
facility.
• Portable electric / hydraulic operator for manually operated
gates.
|