JASH C.I. WEIR GATES
    

Specifications


These gates are made as per JASH design.
  
Application
These gates are downward opening type gates and can be used either for:
  1. Decanting of a reservoir or a tank, or
  2. For maintaining precise level control in a reservoir or a tank, or
  3. To control the flow into or from a conduit as a sluice gate in locations where clearance between the opening and the gate operating floor is inadequate to allow raising of gate to raise to full opening.
Salient Features
  • Designed for channel application, breast wall not required.
  • Suitable for seating head application.
  • Rising spindle Self Contained gate with lift mechanism mounted directly on gate frame.
  • Complete continuous sealing on sides and bottom of gate aperture at any position of shutter opening.
  • Metal to rubber sealing arrangement on three sides.
  • Manual lift mechanism to enable a single person to operate gate with effort < 20Kgs.
  • Painting : 2 coats of redoxide primer with 2 coats of black bitumin paint.
Materials of Construction
Depending upon application and requirement, the client should select and specify the Materials of Construction for various components from offered alternatives.
Shop Testing Parameters
  • Seat clearance check for checking clearance between mating sealing faces.
  • Movement test for checking interference free movement of complete assembly.
  • Leakage test at atmospheric pressure if weir gate provided with sealing on all four sides for application (iii) above.
Optional Features
  • Electrically or Pneumatically operated lift mechanism with manual override facility.
  • Wall thimble mounting design.
  • Gate opening indicating arrangement.
  • Additional sealing on top side for flow control into or from a conduit for application (iii).
  • Lift mechanism mounted on platform away from gate frame.
  • Epoxy primer and epoxy finish paint.